CTE PVI 2400W

1.>90%
Discharging efficiency of battery's useable energy is over 90%
2.ow
Anti-reflux power accuracy is aw
3.<30min
Installation time is less than 30min
4.2400W
Output of UPS is maximum 2400W
5.<10ms
The instantaneous UPS switch over less than 10ms critical load never lases pawer
6.>99%
Aftersakes contentment of APP&Web is over 99%
7.Wall-mounted& Ground
installation method

DESCRIPTION

Model

CTE-DINV024-B3

Basic Parameters

Rated Power

2400VA/2400W

Peak Power

4800W

Machine Architecture


Bidirectional AC/DC Inverter / Buck-boost MPPT

Number of Input and Output Phases

Single Phase Input/Output

Work Mode

Automatic charging: Automatically charge the battery when connectto the grid, and automatically charge the battery when connect to the photovoltaic

Automatic discharging: Manually start the device and automatically feed the power to the grid

Off-grid mode (UPS): Grid supplys the power to loads directly, automatically switchover UPS supply when the grid outage(<10ms)

Output

Strings of Output

Single-phase, two-wire(L,N)+Ground wire

Rated Voltage

220/230/240VAC

Output Voltage Accuracy

±1%

Output Frequency

50/60Hz±0.1%(Automatic detection of grid frequency can be set)

Output Waveform

Pure Sine Wave

Output Distortion(THDi%)

2%(Linear load)

7%(Nonlinear load)

Overload Capacity

5 Min@105%~120%Rated Load

10s@120%~150%Rated Load

2s@>150%Rated Load

Efficiency

Grid Charging (AC-> Battery)

Min 93% (Basic)

Battery Discharge (battery-> AC)

Min 92% (Basic)

MPPT

99.9%

PV Charging Efficiency

96%

Eco Mode

<3W(Dormancy,No Output); <30W(No Load

Shutdown Leakage Current

<100uA

Grid Input

Strings of Input

Single-phase two-wire(L,N)+Ground wire

Input Voltage Range

Earth /Live Phase Voltage: 184Vac~264Vac

Input Frequency Range

48Hz-52Hz(50Hz)/57-63Hz(60Hz)

Input Power Factor

≥0.95

Battery and Charge

Rated Capacity

2.5kWh

Useable Energy

2.3kWh

Max Dis/Charge Depth

90%

Rated Battery Voltage

51.2V

Battery Type

LFP 16 strings

Charge Control Method

Pre-charge, Constant Current, Constant Voltage, Uniform Charge, Float Charge, Shutdown

Charge Suspend Voltage 

56.8V/Continuously Adjustable

Discharge Suspend 

44V/Continuously Adjustable

Voltage

Charge Current

Max 25A, Can be Set Digitally, Default 10A

Charge Control Command

Charge Termination Voltage, Charging Vurrent, Charge Enablement,

Charge Fullness, Battery Failure, Charge Mode Switch

Protection Feature

Overload Protection, Over-Temperature Protection, Input Over-Voltage Protection,

Input Under Voltage Protection, Over-Charge Protection, Over-Discharge Protection

Solar Charge

PV Max Input Power

800W*2

PV Max Open-Circuit Voltage

100VDC

PV Operating Voltage Range

10~100VDC

PV Input Current

PV Insert MPPT Working Mode, 20A max

General Parameter

Grid-Connected Power

The grid-connected power can be set to 0~2400W

(the default grid-connected power is less than 800W, and it can be used spontaneously with anti-reflux function)

Parallel Connection Number

2-6pcs

Customer APP(WIFI Bluetooth Module Customer)

Mobile APP manages and controls grid-connected time and power, on-grid standard selection, etc

Communication Interface

Switch on and off Command Interface, RS485, Anti-reflux

LED Indicator

Operating status: normal, alarm, fault

Software Update

Remote/Local upgrade

Operating 

-20~55°C

Temperature Range

Operating Humidity Range

0-98%(No Condensation)

Cooling Method

Natural Cooling

Dimension

470*570*165 mm (Radiator Size Included)

Weight (kg)

30KG (Radiator and Magnetics Included)

Insulation Isolation withstand Voltage

The battery is insulated from the AC end to withstand voltage: 4242VDC Leakage Current<1mA

Safety and Electromagneti

Compatibility Standards

IEC60950/UL60950/GB4943/IEC61000/IEC62619

/IEC62040/VDE4105 and Other Relevant European Standards